With this setup, the camera went from around 26 °C to nearly zero. I then needed to examine what that cooling changed in the images.
- The repurposed cooler
- €11.19
- Camera temperature
- ≈26 → 0–1 °C
- At the socket, for the complete cooling setup
- ≈ +9 W
But are the images actually better?
Summary report — IMX477 · Peltier campaignMeasurements, figures and conclusions from the EIP campaign. Read the PDF report1. With the lens cap on, it is not quite silent
A camera heats up as it works: its electronics consume energy, some of which becomes heat. In daylight this may not be the main concern. In astronomy, however, I may let the camera collect very faint light for several minutes. When listening for a whisper, background noise matters.
Even with the lens cap on, the sensor still produces some signal and noise. Reading the pixels adds small fluctuations: this is read noise. Some pixels stand out more than their neighbours. Heat can also slowly generate charge, even without light.
That last contribution has a name: dark current. In the first article, I had not managed to measure it reliably for a typical pixel. That prompted an idea: cool the camera further. Would it finally become easier to observe in the dark?
2. First, two small fans
I started by preventing the camera from getting too hot. Two extra fans blew towards the back of its circuit board. No active refrigeration, just moving air to remove some heat.
In a room at around 23 to 24 °C, the camera stayed between 25 and 27 °C during long acquisitions. This already helped limit heating. But a fan is not a refrigerator: I needed something else to get much cooler.
3. An €11 smartphone cooler
Instead of starting with laboratory equipment, I looked at what I already had. A small phone cooler, bought for €11.19 in July 2023, was waiting for a new job. A fan, two power settings and a small square module: enough to try the experiment.

The module transfers heat from one side to the other: one side cools while the other heats up. This is the Peltier effect. The fan removes this heat, along with the heat generated by the device itself.
One practical question remains: the contact surface designed for a phone cannot simply be attached anywhere on the camera.
4. Open, clean and fit
I removed the original contact surface to reach the module, then cleaned off the thermal paste. The small square is marked FZ-2302. I have not identified its electrical specifications with certainty. The results therefore concern the setup as I used it, without assigning unverified specifications to the module.




The pad is a flexible interface that provides a path for heat. It contacts the printed circuit board (PCB), not the sensor silicon. Heat travels through the board and camera structure before reaching the cooler.
- Camera
- PCB
- Pad
- Peltier
- The module
- About 25 mm per side
- The setting
- Maximum power
- The thermostat
- None
What about power consumption?


This is not the Peltier module's power alone. The increase includes the module, its fan, electronics and differences in power-supply losses.
Measurement is taken on the mains side, before the power supply. The wattmeter details and limitations are in the Scientific version. With thermal contact established, it was time to test.
5. The camera approaches zero degrees
At maximum power, temperatures recorded during long exposures fall from around 26 °C to 0 to 1 °C.
Fan cooling alone
Observed range
25–27 °C
Peltier at maximum power
Observed range
0–1 °C
About 25 °C cooler
No thermostat, no zero-degree setpoint.
The system has no thermostat. It runs at full power, and the temperature reached depends on the module, contact and surroundings. Near zero therefore does not mean regulated to exactly zero. Ambient conditions during the cold campaign were not documented.
I used the same exposure times and number of dark frames, up to 300 seconds, with pauses between series.
6. Is the image cleaner, then?
The temperature drop is clear. To assess its value in the images, the dark signal, hot pixels and background structures must be examined separately.
- TemperatureA very large drop≈26 °C → 0–1 °C.
- Abnormally bright pixelsFewer flagged by the analysisBut the detection threshold adapts.
- Image backgroundStill structuredSome variations are less pronounced.
- Thermally generated signalStill too difficult to measureI still cannot assign it a reliable value.
Some pixels produce much more dark signal than their neighbours. They are called hot pixels: the few bright squares in the first diagram illustrate this idea without reproducing the camera's actual pixels.
The other measured sensor properties remain broadly similar between campaigns. These two tests cannot attribute small differences to cooling. Nor did I compare two astronomical photographs to demonstrate a gain in final image quality: the evidence here comes from dark frames.
7. Not everything disappears
Even in darkness, the background is not perfectly uniform. To see it, I combine the 300-second images and show their slow variations. Contrast is deliberately amplified strongly: what looks like a large patch corresponds to tiny differences.


Full-size warm map · Full-size cold map · View detailed measurements
Several measured variations are slightly less pronounced in the cold campaign, but the patterns remain. That is interesting, but two tests are not enough to claim cooling is the only cause. Checking that would require repeating the warm/cold experiment several times with the same analysis rules.
8. The signal that still escapes measurement
I thought strong cooling would finally let me distinguish the charge generated in the dark. The question remains open: I still cannot separate the charge I am looking for from the system's electronic variations. Some of those even shift the background of many pixels together.
Isolating this contribution also requires a better measurement method. If cooling reduces the thermal contribution, it may become even harder to distinguish. But these two campaigns do not measure how much it might have decreased.
The background level shifts slightly during long exposures, sometimes downwards. These shifts obscure the contribution I am trying to measure. I still cannot give a reliable value for a typical pixel's dark current, either warm or cold. Unmeasured does not mean zero. The Scientific version details this limitation.
The setup works: a smartphone cooler at maximum power brings the camera close to zero degrees, without a thermostat and for roughly 9 W extra at the socket. Some background variations are smaller in this campaign, but patterns persist. The next task is to separate their contributions better.
What this experiment taught me
- A small Peltier module can cool the Raspberry Pi HQ substantially in this setup.
- Some imperfections are less pronounced in the cold campaign.
- Sensor patterns do not all disappear.
- A weaker signal can become harder to measure.
What I still do not know
A reliable value for a typical pixel's dark current. These two campaigns do not quantify its decrease.
How do you measure an almost invisible dark current? That is the next article's question.
Continue reading
Other version
Scientific version · Protocol, measurements, models and limitations.