Discovery version · Article 2

Cooling the Raspberry Pi HQ: what do you actually gain?

An €11 smartphone cooler, a Raspberry Pi HQ and a question: how far can this camera be cooled, and does that actually improve the images?

Raspberry Pi HQIMX477PeltierLong exposure

With this setup, the camera went from around 26 °C to nearly zero. I then needed to examine what that cooling changed in the images.

The repurposed cooler
€11.19
Camera temperature
≈26 → 0–1 °C
At the socket, for the complete cooling setup
≈ +9 W

But are the images actually better?

Summary report — IMX477 · Peltier campaign6 October 2026Measurements, figures and conclusions from the EIP campaign. Read the PDF report

1. With the lens cap on, it is not quite silent

A camera heats up as it works: its electronics consume energy, some of which becomes heat. In daylight this may not be the main concern. In astronomy, however, I may let the camera collect very faint light for several minutes. When listening for a whisper, background noise matters.

Conceptual diagram Two small grids: ideal darkness is uniform; a real readout can fluctuate and contain a few brighter pixels.
Conceptual illustration, not to scale. These drawn pixels do not come from EIP campaigns.

Even with the lens cap on, the sensor still produces some signal and noise. Reading the pixels adds small fluctuations: this is read noise. Some pixels stand out more than their neighbours. Heat can also slowly generate charge, even without light.

That last contribution has a name: dark current. In the first article, I had not managed to measure it reliably for a typical pixel. That prompted an idea: cool the camera further. Would it finally become easier to observe in the dark?

2. First, two small fans

I started by preventing the camera from getting too hot. Two extra fans blew towards the back of its circuit board. No active refrigeration, just moving air to remove some heat.

Photograph of the setup Two small fans installed behind the PiNox camera.
The first solution: forced ventilation. The Peltier in the setup was not active during the warm campaign.

In a room at around 23 to 24 °C, the camera stayed between 25 and 27 °C during long acquisitions. This already helped limit heating. But a fan is not a refrigerator: I needed something else to get much cooler.

3. An €11 smartphone cooler

Instead of starting with laboratory equipment, I looked at what I already had. A small phone cooler, bought for €11.19 in July 2023, was waiting for a new job. A fan, two power settings and a small square module: enough to try the experiment.

Phone cooler viewed from the fan side.
Photograph of the device repurposed for the experiment.
Conceptual diagramHeat travels from the camera board through the pad and Peltier module, then is removed by the hot-side fan.
Schematic, not to scale. The Peltier module moves heat; the hot side must then dissipate it.

The module transfers heat from one side to the other: one side cools while the other heats up. This is the Peltier effect. The fan removes this heat, along with the heat generated by the device itself.

One practical question remains: the contact surface designed for a phone cannot simply be attached anywhere on the camera.

4. Open, clean and fit

I removed the original contact surface to reach the module, then cleaned off the thermal paste. The small square is marked FZ-2302. I have not identified its electrical specifications with certainty. The results therefore concern the setup as I used it, without assigning unverified specifications to the module.

Round surface originally intended to touch the phone.
1 OpenRemove the phone contact plate.
Square Peltier module exposed after opening the cooler.
2 ExposeReach the module and clean off the thermal paste.
Back of the camera circuit board before fitting the thermal interface.
3 PrepareExpose the back of the circuit board.
Square thermal pad placed on the camera circuit board.
4 CoupleFit the pad, then bring the cold side into contact.

The pad is a flexible interface that provides a path for heat. It contacts the printed circuit board (PCB), not the sensor silicon. Heat travels through the board and camera structure before reaching the cooler.

  1. Camera
  2. PCB
  3. Pad
  4. Peltier
The module
About 25 mm per side
The setting
Maximum power
The thermostat
None

What about power consumption?

Wattmeter displaying 4.7 W for the Raspberry Pi alone.
Pi alone≈4.7 WMeasured at the socket.
Wattmeter displaying 14.0 W for the Pi and cooler at maximum power.
Pi + cooler14.0 WMeasured at the socket, at maximum power as in the cold campaign.
About 9 W extra at the socket

This is not the Peltier module's power alone. The increase includes the module, its fan, electronics and differences in power-supply losses.

Measurement is taken on the mains side, before the power supply. The wattmeter details and limitations are in the Scientific version. With thermal contact established, it was time to test.

5. The camera approaches zero degrees

At maximum power, temperatures recorded during long exposures fall from around 26 °C to 0 to 1 °C.

Experimental data

Fan cooling alone

≈26 °C

Observed range
25–27 °C

Peltier at maximum power

0–1 °C

Observed range
0–1 °C

About 25 °C cooler

No thermostat, no zero-degree setpoint.

Long-exposure temperatures from the two EIP campaigns. This comparison is not an animation of the actual cooling process.

The system has no thermostat. It runs at full power, and the temperature reached depends on the module, contact and surroundings. Near zero therefore does not mean regulated to exactly zero. Ambient conditions during the cold campaign were not documented.

I used the same exposure times and number of dark frames, up to 300 seconds, with pauses between series.

6. Is the image cleaner, then?

The temperature drop is clear. To assess its value in the images, the dark signal, hot pixels and background structures must be examined separately.

  • TemperatureA very large drop≈26 °C → 0–1 °C.
  • Abnormally bright pixelsFewer flagged by the analysisBut the detection threshold adapts.
  • Image backgroundStill structuredSome variations are less pronounced.
  • Thermally generated signalStill too difficult to measureI still cannot assign it a reliable value.

Some pixels produce much more dark signal than their neighbours. They are called hot pixels: the few bright squares in the first diagram illustrate this idea without reproducing the camera's actual pixels.

The other measured sensor properties remain broadly similar between campaigns. These two tests cannot attribute small differences to cooling. Nor did I compare two astronomical photographs to demonstrate a gain in final image quality: the evidence here comes from dark frames.

7. Not everything disappears

Even in darkness, the background is not perfectly uniform. To see it, I combine the 300-second images and show their slow variations. Contrast is deliberately amplified strongly: what looks like a large patch corresponds to tiny differences.

Experimental data · same contrast
Greyscale map of slow background variations in the warm campaign, with sharply defined cells.
Fan cooling alone · ~26 °C
Background map with Peltier cooling at 0–1 °C, at the same contrast and orientation.
Peltier at maximum power · 0–1 °C
Fan cooling · ~26 °CPeltier · 0–1 °C
Maps from the two campaigns at 300 s, with the same orientation and greyscale. Small squares come from the analysis grid, not physical squares inside the sensor.

Full-size warm map · Full-size cold map · View detailed measurements

Several measured variations are slightly less pronounced in the cold campaign, but the patterns remain. That is interesting, but two tests are not enough to claim cooling is the only cause. Checking that would require repeating the warm/cold experiment several times with the same analysis rules.

8. The signal that still escapes measurement

I thought strong cooling would finally let me distinguish the charge generated in the dark. The question remains open: I still cannot separate the charge I am looking for from the system's electronic variations. Some of those even shift the background of many pixels together.

Conceptual illustration
Conceptual illustration, not a quantitative representation of the measurements. The bars and marker have no physical unit; they only explain the difficulty of separating a small signal from other variations.

Isolating this contribution also requires a better measurement method. If cooling reduces the thermal contribution, it may become even harder to distinguish. But these two campaigns do not measure how much it might have decreased.

The background level shifts slightly during long exposures, sometimes downwards. These shifts obscure the contribution I am trying to measure. I still cannot give a reliable value for a typical pixel's dark current, either warm or cold. Unmeasured does not mean zero. The Scientific version details this limitation.

The setup works: a smartphone cooler at maximum power brings the camera close to zero degrees, without a thermostat and for roughly 9 W extra at the socket. Some background variations are smaller in this campaign, but patterns persist. The next task is to separate their contributions better.

What this experiment taught me

  • A small Peltier module can cool the Raspberry Pi HQ substantially in this setup.
  • Some imperfections are less pronounced in the cold campaign.
  • Sensor patterns do not all disappear.
  • A weaker signal can become harder to measure.

What I still do not know

A reliable value for a typical pixel's dark current. These two campaigns do not quantify its decrease.

How do you measure an almost invisible dark current? That is the next article's question.

Continue reading

Other version

Scientific version · Protocol, measurements, models and limitations.

In this series

  1. Article 1 · DiscoveryCharacterising the IMX477
  2. Article 2 · DiscoveryCooling the Raspberry Pi HQ
  3. Article 3 · Coming laterHow do you measure an almost invisible dark current?